700kW Natural Gas Turbine Generator

It has the characteristics of high machining and assembly accuracy, high efficiency, high degree of automation, strong load-bearing capacity and load impact resistance, strong universality of accessories, and low unit operation and maintenance costs.

  Contact Now E-Mail Telephone
Product Details

The 700kW  gas turbine generator set is an innovative product in our company's product series. After years of dedicated research, the product has integrated rich successful experience in 12V190 gas engine research and technology application, and the automation capability of the unit has been greatly enhanced.

700kW

MAIN SPECIFICATIONS OF 700kW Natural Gas Generator

Generator Model

700GF-TK


Gas Engine Model

12V190ZDT-2

Power

700kW/875KVA


Alternator

Siemens Series

Voltage

400V


Starting method

24V DC electric start

Speed

1000rpm


Coupling method

Elastic coupling

Frequency

50Hz


Voltage regulation

Automatic/AVR

Current

1263A


Cooling Mode

Water cooling with Flat bed radiator

Power factor

0.8 Lagging


Heat Consumption

£ 9500kJ/kWh

Control mode

Electric control


Overall dimension (mm)

5120×2040×2780


Net Weight (kg)

15200

 MAIN ELECTRICAL PERFORMANCE OF THE GAS GENERATOR

Voltage

Stabilized regulation

Instantaneous regulation

Recovery time

Fluctuation

±2.5%

+20%

2 S

1%

Frequency

Stabilized regulation

Instantaneous regulation

Recovery time

Fluctuation

0-5% adjustable

+10%,-12%

< 10 S

1%

 MAIN SPECIFICATIONS OF GAS ENGINE

Model

M12V190ZL

Rated power

700kW/875KVA

Number and layout of cylinders:

12-cylinders, V-type, 60° included angle

Type

Four strokes, Closed type water cooled, Turbo-charged, Electronic ignition, Electronic speed governor

Ignition type

Spark plug ignition

Gas pressure required

100-400kPa

Bore´Stroke

190´210 mm

Speed Governor

(Woodward) EGS-06 Electric governor

Oil consumption

£ 0.6g/kWh

Total lubricating oil capacity (Liters)

200L

Exhaust temperature (before turbine)

£ 680 °C

Heavy overhauling period

36,000h

MAIN SPECIFICATIONS OF ALTERNATOR

Alternator model

Exciting model

Insulation class

Connection

Cooling

Structure type

1FC5456-6TA42 (SIEMENS)

Brushless

Class F

3-phase, 4-wire

Air cooled

AVR and reactive droop regulator assembled in alternator

(Kindly Noted: data shown in above table tested under standard working condition: 25 Dec C, atmospheric pressure 100kPa, relative humidity 30%, altitude <1000m.)