2000GF-T Natual Gas Generator

Advanced configuration keep accurate ans stable working condition under high speed working speed
High generalization, easy maintenance, low maintenance cost.
Economical, low operating cost
Reduced the carbon deposition on the wear of the engine cylinder and the valve to prolong the using life of the genset.
Adopt one of the world's most advanced gas control technology, fully available to the characteristics of fuel gas.
Powerful low pressure gas SPI (single point Injection) system used for various supercharger premixed engine.
Suitable for differnt concentration methane and propane, variety of quality gas.
Precise air-fuel ratio rarefied combustion control and Generator speed/load control
Realize lean burn, reduce the intake pipe tempering and improved efficient to reduce the heat load.

  Contact Now E-Mail Telephone
Product Details

Jichai Brand Generator is designed and manufactured to be excessive quality, lengthy utilization life, effortless operation, low protection cost, excessive brain with low engine speed, low gas consumption, low fuel best requirement, difficult environmental adaptability, excessive steadiness and low fluctuation. The generator is acceptable for industrial strength solution.

2000GF9-T(2000kW) natural gas generating set are powered by model L20V190ZLT-1 gas engine produced by our company. Complying with National Standard “GB2820 General Specification for Industrial Frequency Diesel Generating Sets(eqv ISO 8528)” and with reference to “IEC34-I” rotary generator standard, the sets are equipped with high quality alternator of both home & abroad and self-made control panel according to customers requirement Engine Design.

2000GF-T Natual Gas Generator

MAIN SPECIFICATIONS OF GAS GENERATOR SET

Model

2000GF-T


Gas Engine Model

L20V190ZLT-1

Rated power

2000kW/2500KVA


Alternator

Siemens Series

Rated voltage

10.5kV


Starting method

24V DC electric start

Rated speed

1000rpm


Voltage regulation

Automatic

Rated frequency

50Hz


Cooling Mode

Close type water cool

Rated current

137.5A


Heat Consumption

9200kJ/kWh

Power factor

0.8 Lagging


Dimension (mm)

9583x2180x2540mm

Control mode

Electric control


Net Weight (kg)

28000


MAIN ELECTRICAL PERFORMANCE OF THE GAS GENERATOR

Voltage

Stabilized regulation

Instantaneous regulation

Recovery time

Fluctuation

±2.5%

+20% - 15%

1.5S

0.5%

Frequency

Stabilized regulation

Instantaneous regulation

Recovery time

Fluctuation

0-5% adjustable

+10%,-10%

< 7 S

0.5%


MAIN SPECIFICATIONS OF GAS ENGINE

Model

L20V190ZLT-1

Rated power

2000kW (2500KVA)

Number and layout of cylinders:

20-cylinders, V-type, 60° included angle

Type

Four strokes, Closed type water cooled, Turbo-charged, Electronic ignition, Electronic speed governor

Ignition type

Spark plug ignition

Intake gas pressure required

100-400 kPa before gas pressure regulator

Bore´Stroke

190´255 mm

Speed Governor

(Woodward) Electric governor

Oil consumption

£ 0.3g/kWh

Total lubricating oil capacity (Liters)

600L

Exhaust temperature (before turbine)

£ 680 °C

Heavy overhauling period

36,000h

MAIN SPECIFICATIONS OF ALTERNATOR
 


Alternator model

Exciting model

Insulation class

Connection

Cooling

Structure type

1FC series
(SIEMENS)

Brushless

Class F

3-phase, 3-wire

Air cooled

AVR and reactive droop regulator assembled in alternator


 2000GF-T Natual Gas Generator(Kindly Noted: data shown in above table tested under standard working condition: 25 Dec C, atmospheric pressure 100kPa, relative humidity 30%, altitude <1000m.)


CONTROL PANEL

Control panel is panel type, vertical structure, mannequin is GPL2000. Control panel is geared up with meters displaying more than a few parameters of working status, computerized air swap and timer. All of the electric powered cells possess three-proof functions.

The Generator possesses the following automated monitoring and shielding functions:

A) Audio or visible alarm for:
-   High oil and water temperature
-   Low oil pressure
-   Over current
-   Short circuit
-   Over-speed
-   Reverse power
B) Shut-off for:
-   Low oil pressure
-   Over-speed
-   Short circuit
-   Over-speed
-   Reverse power
C) Trip-off for:
-   Over-current
-   Short circuit
-   Reverse power
The generator can now not solely provide electricity without delay to load however additionally can be paralleled running.

OPTIONAL DEVICE
Steel Soundproof Container (sound attenuated canopy)
CHP/ Cogeneration/CCHP Trigeneration
ATS and Synchronization Parallelling Panel
Oil and Water Heater

Sale Service

1. Pre Sales: Solution Delivery

2. On sale: provision of technical services

3. Provision of after-sales full lifecycle technical services

Sale Service

Delivery

Delivery

Production line

Production line

Hot Sale Products


Hot Sale Products


Leave your messages

Related Products

Popular products