2000GF-T Natual Gas Generator
Advanced configuration keep accurate ans stable working condition under high speed working speed
High generalization, easy maintenance, low maintenance cost.
Economical, low operating cost
Reduced the carbon deposition on the wear of the engine cylinder and the valve to prolong the using life of the genset.
Adopt one of the world's most advanced gas control technology, fully available to the characteristics of fuel gas.
Powerful low pressure gas SPI (single point Injection) system used for various supercharger premixed engine.
Suitable for differnt concentration methane and propane, variety of quality gas.
Precise air-fuel ratio rarefied combustion control and Generator speed/load control
Realize lean burn, reduce the intake pipe tempering and improved efficient to reduce the heat load.
Jichai Brand Generator is designed and manufactured to be excessive quality, lengthy utilization life, effortless operation, low protection cost, excessive brain with low engine speed, low gas consumption, low fuel best requirement, difficult environmental adaptability, excessive steadiness and low fluctuation. The generator is acceptable for industrial strength solution.
2000GF9-T(2000kW) natural gas generating set are powered by model L20V190ZLT-1 gas engine produced by our company. Complying with National Standard “GB2820 General Specification for Industrial Frequency Diesel Generating Sets(eqv ISO 8528)” and with reference to “IEC34-I” rotary generator standard, the sets are equipped with high quality alternator of both home & abroad and self-made control panel according to customers requirement Engine Design.
MAIN SPECIFICATIONS OF GAS GENERATOR SET
Model | 2000GF-T | Gas Engine Model | L20V190ZLT-1 | |
Rated power | 2000kW/2500KVA | Alternator | Siemens Series | |
Rated voltage | 10.5kV | Starting method | 24V DC electric start | |
Rated speed | 1000rpm | Voltage regulation | Automatic | |
Rated frequency | 50Hz | Cooling Mode | Close type water cool | |
Rated current | 137.5A | Heat Consumption | 9200kJ/kWh | |
Power factor | 0.8 Lagging | Dimension (mm) | 9583x2180x2540mm | |
Control mode | Electric control | Net Weight (kg) | 28000 |
MAIN ELECTRICAL PERFORMANCE OF THE GAS GENERATOR
Voltage | |||
Stabilized regulation | Instantaneous regulation | Recovery time | Fluctuation |
±2.5% | +20% - 15% | 1.5S | 0.5% |
Frequency | |||
Stabilized regulation | Instantaneous regulation | Recovery time | Fluctuation |
0-5% adjustable | +10%,-10% | < 7 S | 0.5% |
MAIN SPECIFICATIONS OF GAS ENGINE
Model | L20V190ZLT-1 |
Rated power | 2000kW (2500KVA) |
Number and layout of cylinders: | 20-cylinders, V-type, 60° included angle |
Type | Four strokes, Closed type water cooled, Turbo-charged, Electronic ignition, Electronic speed governor |
Ignition type | Spark plug ignition |
Intake gas pressure required | 100-400 kPa before gas pressure regulator |
Bore´Stroke | 190´255 mm |
Speed Governor | (Woodward) Electric governor |
Oil consumption | £ 0.3g/kWh |
Total lubricating oil capacity (Liters) | 600L |
Exhaust temperature (before turbine) | £ 680 °C |
Heavy overhauling period | 36,000h |
MAIN SPECIFICATIONS OF ALTERNATOR
Alternator model | Exciting model | Insulation class | Connection | Cooling | Structure type |
1FC series | Brushless | Class F | 3-phase, 3-wire | Air cooled | AVR and reactive droop regulator assembled in alternator |
(Kindly Noted: data shown in above table tested under standard working condition: 25 Dec C, atmospheric pressure 100kPa, relative humidity 30%, altitude <1000m.)
CONTROL PANEL
Control panel is panel type, vertical structure, mannequin is GPL2000. Control panel is geared up with meters displaying more than a few parameters of working status, computerized air swap and timer. All of the electric powered cells possess three-proof functions.
The Generator possesses the following automated monitoring and shielding functions:
A) Audio or visible alarm for:
- High oil and water temperature
- Low oil pressure
- Over current
- Short circuit
- Over-speed
- Reverse power
B) Shut-off for:
- Low oil pressure
- Over-speed
- Short circuit
- Over-speed
- Reverse power
C) Trip-off for:
- Over-current
- Short circuit
- Reverse power
The generator can now not solely provide electricity without delay to load however additionally can be paralleled running.
OPTIONAL DEVICE
Steel Soundproof Container (sound attenuated canopy)
CHP/ Cogeneration/CCHP Trigeneration
ATS and Synchronization Parallelling Panel
Oil and Water Heater
Sale Service
1. Pre Sales: Solution Delivery
2. On sale: provision of technical services
3. Provision of after-sales full lifecycle technical services
Delivery
Production line
Hot Sale Products