Intelivision 5-manufacture,factory,supplier from China

(Total 24 Products for Intelivision 5)
Intelvision 5 has significant features of easy operation, complete functionality, and reliable protection. There are operation buttons on this panel, such as turning on the power, preheating in advance, starting and ending (emergency stop).
  Contact Now
The Intelivision 8 is the most basic configuration that meets the normal operation and use of the unit, and has the advantages of simple operation, complete functions, and reliable protection. The panel has operation buttons such as power on, preheating, start, and stop (emergency stop).
  Contact Now
Main specification of gas generatorGenset model 1100GF-TAlternator model1FC series,siemens technology.Brushless excitation,Automatic voltage regulation.Panel modelGPL1100Rated power1100KWRated voltage400V/10500VRated frequency50HZRated power factor0.8Wiring mood3 Phase 4 Wire/3 Phase 3 WireStabilized voltage regulation±2.5%Voltage stabilization time≤1.5sFluctuation rate of voltage≤1%Stabilized state frequency regulation0-5%Frequency stabilized time rate≤7sFluctuation rate of frequency≤0.5%Overall dimension5998mm*2180mm*2540mmNet weight19800kgMain specification of gas engineEngine modelH16V190Z
  Contact Now
Genset model700GF1-WdAlternator model1FC series,siemens technology.Brushless excitation,Automatic voltage regulation.Panel modelGPL700Rated power700KWRated voltage400V/480V/6300V/10500/13800Rated frequency50/60HZRated power factor0.8Wiring mood3 Phase 4 Wire/3 Phase 3 WireStabilized voltage regulation±2.5%Transient state voltage regulation+20%(-15)Voltage stabilization time≤1.5sFluctuation rate of voltage≤1%Stabilized frequency regulation0~5%Transient state frequency regulation≤±10%Frequency stabilized time rate≤7sFluctuation rate of frequency≤0.5%Overall dimension5120mm*2180mm*2540mmNet weigh
  Contact Now
Main specification of gas generatorGenset model1200GF-TAlternator model1FC series,siemens technology.Brushless excitation,Automatic voltage regulation.Panel modelGPL1100Rated power1100KWRated voltage400V/10500VRated frequency50HZRated power factor0.8Wiring mood3 Phase 4 Wire/3 Phase 3 WireStabilized voltage regulation±2.5%Voltage stabilization time≤1.5sFluctuation rate of voltage≤1%Stabilized state frequency regulation0-5%Frequency stabilized time rate≤7sFluctuation rate of frequency≤0.5%Overall dimension5998mm*2180mm*2540mmNet weight19800kgMain specification of gas engineEngine modelH16V
  Contact Now
500KVA/400KW Diesel Generator powered by Cummins engine:  DIESEL GENERATORGenset Model400GF-D Power (kW/kVA)400/500Voltage400VFrequency50HZDIESEL ENGINE SPECIFICATIONSModelKTA19-G3ATypewater-cooled, in line, 4-stroke, direct injectionOutput Power(kW)440kwIntake TypeTurbochargedNo.of Cylinder6.LBore x Stroke(mm)159x159Compression Ratio14.5:1Mechanical Governor Rate<=5%Electronic Governor Rate<=1%Rated Fuel Consumption(L/h)98Displacement(L)18.9Governing TypeElectricalStart methodElectric startOverload capacity110% ALTERNATOR SPECIFICATIONSBrandSTAMFORDModelHCI
  Contact Now
Jichai Brand Generator is designed and manufactured to be state-of-the-art technology,higher energy efficiency,sustainable high performance,ease of serviceability,longer service life,cleaner emissions.Main specification of gas generatorGenset model 1200GF-TAlternator modelBrushless excitation,Automatic voltage regulation.Panel modelGPL1200Rated power1200KWElectrical efficiency≥38%Rated voltage400V/480V/6300V/10500V/13800Rated frequency50/60HZRated power factor0.8Wiring mood3 Phase 4 Wire/3 Phase 3 WireProtection classIP23Isolation classHStabilized voltage regulation±2.5%Voltage stabilization t
  Contact Now
2000GF9-T(2000kW) natural gas generating set are powered by model L20V190ZLT-1 gas engine produced by our company.
  Contact Now
2000GF-T(2000kW) natural gas generating set are powered by model L20V190ZLT-1 gas engine produced by our company.
  Contact Now
GENERATOR SPECIFICATIONGenset model1000GF-DOutput power1000KW/1250KVAOutput voltage400/230VOutput currency1800ARated frequency50HzRated speed1500rpmDimension12000X2400X2700mmWeight14000kgENGINE SPECIFICATIONSENGINE SPECIFICATIONBrand / Origin CUMMINSEngine modelKTA38-G9 Rated power1090kwNumber of cylinders12.VBore x stroke159X159mmStart methodelectric startCooling methodClosed water circulation coolingGovernor methodElectricalIntake mothodTurbochargedOverload capacity110%Speed1500rpmRated fuel consumption207 L/hOil capacity135  L Displacement37.8 LALTERNATOR SPECIFICATIONAL
  Contact Now
Product name:Hall Sensors Product model:1612T.13K.20Packing&Delivery:In impartial cartons.We additionally provide personalized packing.We generally grant impartial cartons and plywood cases. We additionally provide custom-made packing.
  Contact Now
This natural gas generator adopts - H16V190ZLT 2 engine, which is one sort of highly intelligent, low heat consumption, high reliability, low emission, long lifetime 16V gas engine. H16V190ZLT-2 electrical control and external mix engine owns speed 1000r/min, single unit power 1320kW. With large power reverse, the engine can be used to assemble 1000kW natural gas generator set and equipped machinery.
  Contact Now
The 800kW Natural Gas Engine Generator Jichai Brand Generator is designed and manufactured to be immoderate quality, prolonged utilization life, handy operation, low maintenance cost, immoderate Genius with low engine speed, low gas consumption, low gas fantastic requirement, tough environmental adaptability, immoderate steadiness and low fluctuation.
  Contact Now
700GF-T gas engine generator adopts Jichai 12V190 Engine and Siemens science alternator.
  Contact Now
Jichai Brand Generator is designed and manufactured to be high intelligence with low engine speed, low fuel consumption, low gas quality requirement, tough environmental adaptability, high stability and low fluctuation.
  Contact Now
Jichai Brand Generator is designed and manufactured to be high quality, long usage life, easy operation, low maintenance cost, high intelligence with low engine speed, low fuel consumption, low gas quality requirement, tough environmental adaptability, high stability and low fluctuation.
  Contact Now
Jichai Brand Generator is designed and manufactured to be high quality, long usage life, easy operation, low maintenance cost, high intelligence with low engine speed, low fuel consumption, low gas quality requirement, tough environmental adaptability, high stability and low fluctuation.
  Contact Now
Jichai Brand Generator is designed and manufactured to be state-of-the-art technology,higher energy efficiency,sustainable high performance,ease of serviceability,longer service life,cleaner emissions.Main Specification Of Gas GeneratorModel1000GF-TEngine modelL12V200ZLT-2Rated power1000KW/1250KVARated frequency50/60HzPower factor0.8(Lag)Rated voltage400/6300/10500VRated speed1000r/minOil consumption≤1.0g/kWhStarting methodElectrical starter DC24VCooling methodClosed water coolingControl methodElectric controlConnection methodHigh elastic couplingSteady state voltage adjustment rate<±2
  Contact Now
4000kW natural gas generating sets (4000GF70-T) are powered by model 16V26/32T gas engine produced by Jinan Jichai company.It has the features of accurate voltage regulating, good dynamic performance, less voltage waveform distortion, high efficiency, compact structure, easy to maintain, low speed, good reliability, long life operation and cost-effective.  Main Specification of 4000GF70-T Gas generator                   Model of genset4000GF70-TModel of engineH16V260ZLT-2Model of alternator1FC6 SeriesCoupling methodElastic couplingRat
  Contact Now
Jichai Brand Generator is designed and manufactured to be high quality, long usage life, easy operation, low maintenance cost, high intelligence with low engine speed, low fuel consumption, low gas quality requirement, tough environmental adaptability, high stability and low fluctuation. The generator is desirable for industrial power solution.2000GF-T(2000kW) natural gas generating set are powered by model L20V190ZLT-1 gas engine produced by our company.
  Contact Now
Jichai Brand Generator is designed and manufactured to be excessive quality, lengthy utilization life, effortless operation, low protection cost, excessive brain with low engine speed, low gas consumption, low fuel best requirement, difficult environmental adaptability, excessive steadiness and low fluctuation. The generator is acceptable for industrial strength solution.2000GF9-T(2000kW) natural gas generating set are powered by model L20V190ZLT-1 gas engine produced by our company.
  Contact Now
The 500kw 600kW natural gas generator has the traits of excessive machining and assembling precision, excessive thermal efficiency, excessive diploma of automation, robust carrying potential and load influence resistance, robust versatility of accessories, low operation and protection costs. Main specification of 500-600kW gas generatorGenset model 500GF-T600GF-TAlternator modelBrushless excitation,Automatic voltage regulation.Panel modelGPL500GPL600Rated power500KW600kwRated voltage400V/480V/6300V/10500/13800Rated frequency50/60HZRated power factor0.8Wiring mood3 Phase 4 W
  Contact Now
This landfill gas generator adopts - L20V190ZLZ-2 engine, which is one sort of highly intelligent, low heat consumption, high reliability, low emission, long lifetime 16V gas engine.  L20V190ZLZ-2 electrical control and external mix engine owns speed 1000r/min.With large power reverse, the engine can be used to assemble 2000kW landfill gas generator set and equipped machinery.
  Contact Now
The 1500kVA Natural Gas Engine Generator is equipped with H16V190 Gas engine as the prototype, and has developed an engine terrific for low stress gas, immoderate intelligence, low heat consumption, excessive reliability, low emissions, prolonged life, immoderate electricity and immoderate performance.Through the existence like matching of the consumption system and the adoption of the world's most best manipulate mode, the engine can adapt to the methane cognizance widely, and its power, economy, safety and reliability have reached the international most effective stage.MAIN SPECIFICATION
  Contact Now
Relate News
In November 2024, 5 sets of 700kW gas engine generator sets completed factory acceptance and shipped to Ghana successfully. 700kW gas engine generator adopts Jichai 12V190 Engine and Domestic first-tier brands technology alternator.
Read the manual: Before operating gas enigne generator set, carefully read and understand the user manual provided by the manufacturer. Familiarize yourself with the operating procedures, safety precautions, and maintenance requirements specific to your generator set model. Ensure proper ventilation: Gas engine generator sets produce exhaust gases during operation.
Characteristics of InteliSys gas controller for generator sethe main controller system is a dedicated generator set controller that integrates monitoring,control,regulation and protection.Generator set controller:1. The special controller is combined with monitoring, control, adjustment and protection, makes generator set running both synchronously and parallelly.2. Adopting modular design, could increase extended module via CAN, meet the requirement of various parameter collection and control. 32 generator sets could parallel run via CAN.3.
Internal gas engine generator set is a device that uses an internal gas engine as the power source to drive the generator for power generation. The output power of the internal combustion engine generator set is generally between 10 kW and 5000 kW. The internal engine generator set is mainly used as a backup power source. When the mains power is interrupted, the internal gas engine is started to drive the generator for power supply to ensure that the AC power supply will not be interrupted for a long time.  The gas generator set mainly includes the engine, generator, and controller.
Nigeria Customers has ordered more than 30 sets of 600KW gensets for the phase 1&2. For phase 3, the power station owns 2 set 11kV high voltage genset and 6 set 400V low voltage genset.On Sep 15th, we have completed delivery successfully.
The following precautions should be taken during the operation of the generator set:Regularly check the operation status of the generator set to ensure the normal operation of the equipment.Check the oil, water temperature, battery voltage and other parameters of the generator set to ensure a normal operating environment.Regularly clean the generator set to avoid dust and debris affecting equipment operation.Pay attention to the operating noise and vibration of the generator set, and promptly handle any abnormal situations.Ensure that the safety protection measures of the generator set are int
In December 2024, the spare parts of the natural gas generator set reserved by the customer have been packaged and shipped smoothly. 
When it comes to choosing a gas engine generator, here are some factors to consider:1、Power Requirements: Determine the wattage you need by calculating the total power consumption of appliances and devices that you want to run simultaneously during a power outage. This will help you choose a generator with sufficient capacity to meet your needs.2、Fuel Type: Biogas,biomass or natural gas are common fuel options for gas engine generators.
It is important to maintenance and upkeep the gas engine generator.It can extend the service life and ensure daily normal operation.1.Regular cleaning: Ensure that the generator is regularly cleaned of dust and debris, especially the radiator and ventilation openings.
Advantages of slient container gas engine generator:1)Low noise advantage:silent type realize below 75 decibels meet to international standards; super silent type realize 65 dB below reached the military standards.2)Door and window well sealing:Seamless with stainless steel hinges and high elastic sealing tape make the generator set with a close sealed gap.3)Weather resistance:Silent shield adopts with high-performance stainless steel door locks which open more convenient and improve the weathering performance of the machine.4)Strength advantage:The main components of the silent shield use the